DIP Pumps, Water-Cooled®.



The DIP range of pumps was developed for operation in industrial systems. Excellent vacuum performance data combined with the inherent ruggedness of this kind of pump, make our diffusion pumps pumps a reliable component in high and medium vacuum applications.

Advantages to the User

- High pumping speeds in the fine and high vacuum ranges - Low attainable ultimate pressure
- Integrated, water-cooled cold cap baffle guarantees low oil backstreaming rates into the vacuum chamber
- Low oil losses (even at high gas throughputs) by integrated water cooled forevacuum baffle
- High forevacuum resistance even at reduced heating power
- The heating cartridges are accessible from the outside via heating inserts which are built into the boiler. This ensures a quick exchange of single heating cartridges (even when the pump is hot)
- A separate automatic circuit breaker for each heating cartridge ensures a high level of electrical safety
- A standard built-in thermostat acts as an thermal overload switch and ensures that the heating cartridges can not overheat
- All pumps are prepared for installation with an over-temperature switch (optional) for checking the cooling water circuit, and a contact thermometer (optional) to monitor the operating temperature of the diffusion pump
- Indication of the oil level by sight glass permits simple checking of the current oil level
- All DIP pumps are delivered with their inside chamber cleaned in such a manner that it is free of oil. The inside is evacuated. In the condition as delivered, the pumps may be also operated with silicone oil

Typical Applications

The diffusion pumps from the DIP range are used in coating systems, vacuum melting and drying systems as well as in vacuum furnaces in the area of metallurgy.

Supplied Equipment

The DIP pumps are supplied ready for connection but without the filling of pump fluid.
The inside of the pump is cleaned before delivery to such an extent that it is free of oil. The inside is evacuated. High and forevacuum flanges are equipped with gaskets and centering rings having shipping flanges and complete with clamping components.

Technical DataDIP 3000DIP 8000DIP 12000
High vacuum/forevacuum connection DN
Pumping speed for air
below 1 x 10-4 mbar l/s
Operating range mbar
(Torr)
Ultimate total pressure mbar (Torr)
Max. permissible forevacuum pressure
mbar (Torr)
Pump fluid filling, min. / max. l (qts)
Mains connection
Standard EURO, 50/60 Hz V
Standard Americas, 50/60 Hz V
Special, 50/60 Hz V
Heating power kW
Number of heating cartridges
Heating up time min
Cooling water (minimum)
for pump l/h (gal/min)
for cold cap baffle lh (gal/min)
Max. supply pressure bar (psig)
Number of cooling circuits
(including cold cap baffle)
Cooling water connection
for pump G (BPS)
for cold cap baffle G (BPS)
Weight, approx. kg (lbs)
Recommended backing pump
at operating pressures
> 10-4 mbar (> 0.75 x 10-4 Torr)
at operating pressures
< 10-4 mbar (< 0.75 x 10-4 Torr)
250 ISO-K/63 ISO-K

3000
< 10-2 to 10-7
(0.75 x 10-2 to 0.75 x 10-7)
< 5 x 10-7 (6.7 x 10-7)

6 x 10-1 (4.5 x 10-1)
1.0 / 1.4 (1.1 / 1.5)

230 ~ 1 Ph
230 ~ 1 Ph

2.4
2
< 25

160 (0.7)
20 (0.09)
6 (87)

2

3/8"
1/4"
29 (64)


TRIVAC D 65 B + W 251

TRIVAC D 25 B
400 ISO-K/63 ISO-K

8000
< 10-2 to 10-7
(0.75 x 10-2 to 0.75 x 10-7)
< 5 x 10-7 (6.7 x 10-7)

6 x 10-1 (4.5 x 10-1)
1.7 / 3.4 (1.8 / 3.6)

400 ~ 3 Ph Y
460 ~ 3 Ph Y
230 ~ 3 Ph V
4.8
6
< 25

290 (1.28)
30 (0.13)
6 (87)

2

1/2"
3/8"
70 (154)


DK 200 + W 251

TRIVAC D 65 B + W 251
500 ISO-K/100 ISO-K

12000
< 10-2 to 10-7
(0.75 x 10-2 to 0.75 x 10-7)
< 5 x 10-7 (6.7 x 10-7)

6 x 10-1 (4.5 x 10-1)
2.4 / 5.3 (2.5 / 5.6)

400 ~ 3 Ph Y
460 ~ 3 Ph Y
230 ~ 3 Ph V
7.2
9
< 25

500 (2.2)
50 (0.22)
6 (87)

2

1/2"
3/8"
102 (225)


DK 200 + W 501

TRIVAC D 65 B + W 251
Technical DataDIP 20000DIP 30000DIP 50000
High vacuum/forevacuum connection DN
Pumping speed for air
below 1 x 10-4 mbar l/s
Operating range mbar
(Torr)
Ultimate total pressure mbar (Torr)
Max. permissible forevacuum pressure
mbar (Torr)
Pump fluid filling, min. / max. l (qts)
Mains connection
Standard EURO, 50/60 Hz V
Standard Americas, 50/60 Hz V
Special, 50/60 Hz V
Heating power kW
Number of heating cartridges
Heating up time min
Cooling water (minimum)
for pump l/h (gal/min)
for cold cap baffle lh (gal/min)
Max. supply pressure bar (psig)
Number of cooling circuits
(including cold cap baffle)
Cooling water connection
for pump G (BPS)
for cold cap baffle G (BPS)
Weight, approx. kg (lbs)
Recommended backing pump
at operating pressures
> 10-4 mbar (> 0.75 x 10-4 Torr)
at operating pressures
< 10-4 mbar (< 0.75 x 10-4 Torr)
630 ISO-F/100 ISO-K

20000
< 10-2 to 10-7
(0.75 x 10-2 to 0.75 x 10-7)
< 5 x 10-7 (6.7 x 10-7)

6 x 10-1 (4.5 x 10-1)
5.0 / 9.0 (5.3 / 9.5)

400 ~ 3 Ph Y
460 ~ 3 Ph Y
230 ~ 3 Ph Ä
12
12
< 25

600 (2.6)
60 (0.26)
6 (87)

2

1/2"
3/8"
172 (379)


SV 200 + W 501

TRIVAC D 65 B + W 251
800 ISO-F/160 ISO-K

30000
< 10-2 to 10-7
(0.75 x 10-2 to 0.75 x 10-7)
< 5 x 10-7 (6.7 x 10-7)

6 x 10-1 (4.5 x 10-1)
7.0 / 15.0 (7.4 / 15.9)

400 ~ 3 Ph Y
460 ~ 3 Ph Y
230 ~ 3 Ph Ä
18
18
< 30

900 (4.0)
80 (0.35)
6 (87)

3

1/2"
3/8"
296 (653)


SV 300 + W 1001

DK 200 + W 251
1000 ISO-F/160 ISO-K

50000
< 10-2 to 10-7
(0.75 x 10-2 to 0.75 x 10-7)
< 5 x 10-7 (6.7 x 10-7)

6 x 10-1 (4.5 x 10-1)
12.0 / 25.0 (12.7 / 26.4)

400 ~ 3 Ph Y
460 ~ 3 Ph Y
230 ~ 3 Ph Ä
24
24
< 30

1500 (6.6)
150 (0.66)
6 (87)

3

1/2"
3/8"
560 (1235)


SV 630 + W 2001

DK 200 + W 501