ECODRY® M30
| Technical Data | ECODRY® M30 | |
| 3-phase motor | FC motor | |
|
# of cylinders # of stages Max. pumping speed 50 Hz m3 x h-1 (cfm) 60 Hz m3 x h-1 (cfm) @ 750 rpm 50/60 Hz m3/h (cfm) @ 1000 rpm 50/60 Hz m3/h (cfm) @ 1250 rpm 50/60 Hz m3/h (cfm) Ultimate total pressure 3-phase motor 60 Hz mbar (Torr) FC motor at 1000 rpm 50/60 Hz mbar (Torr) Max. permissible inlet pressure Max. permissible permanent inlet pressure mbar (Torr) Water vapor tolerance (with gas ballast) Leak rate (integral) mbar x l x s^-1 Power consumption at < 10 mbar (7.5) inlet pressure W (hp) Motors 3-phase (IP 54) 50 Hz V 60 Hz V FC motor, 50/60 Hz (IP 44) V Rotational speed with 3-phase motor 50 / 60 Hz rpm with FC motor 50 / 60 Hz rpm via analog interface 0-10 V 50 / 60 Hz rpm Noise level at ultimate pressure without gas ballast (50 Hz at 3-phase and 750 rpm with FC motor) dB(A) Ambient temperature °C (°F) Connection Inlet port fitting DN Exhaust port fitting DN Dimensions, approx. (L x W x H) standard, flanges at motor side vertically installed mm (in.) horizontal installed mm (in.) Weight, approx. kg (lbs) |
4 3 27 (15.9) 30 (17.7) – – – 5.5 x 10-2 (4.1 x 10-2) – Atmosphere 100 (75) 25 (18.8) ≤ 1 x 10-4 450 (0.6) -5 % to +5 % 220-240/346-415 200-277/380-480 – 1000 / 1200 – – ≤ 59 0 to + 50 (32 to + 122) 25 KF 25 KF 709 x 182 x 369 (27.9 x 7.17 x 14.5) 709 x 369 x 211 (27.9 x 14.5 x 8.3) 53 (117) |
4 3 – – 19 (11.2) 25 (14.7) 30 (17.7) – 5.5 x 10-2 (4.1 x 10-2) Atmosphere 100 (75) 25 (18.8) ≤ 1 x 10-4 330 (0.45) – – 90-264 – 750/1000/1200 750-1200, variable ≤ 59 0 to + 50 (32 to + 122) 25 KF 25 KF 713 x 182 x 369 (28.1 x 7.17 x 14.5) 713 x 369 x 211 (28.1 x 14.5 x 8.3) 59 (130.2) |