Chemtech Services, Inc.

Contact Us

Telephone: 815-744-4696

Fax: 815-744-3938

Email Us Directions To Our Facility

RUVAC WS/WSU (W) PFPE Roots Vacuum Pumps with Water-Cooled Canned Motors

Advantages to the UserTypical ApplicationsSupplied Equipment
- Two series, each with four models
- Highly leak-tight air-cooled pumps driven by a water-cooled canned motor
- RUVAC WS/WSU(W) PFPE lubricated with perfluoropolyether (PFPE)
- WS and WS PFPE pumps are identical except for the lubricant and the shipping package
- No thermal problems due to the speed independent cooling arrangement using a separately connected fan, thus no thermal problems at low speeds
- Over-temperature switch in the stator coil of the motor
- All elastomer seals made of FPM/Viton
- Integrated pressure equalization line with differential pressure valve prevents overloading on WSU model
- RUVAC WS 251 to 2001 for use with a frequency inverter for a wide frequency range
- No shaft feedthrough to the atmosphere, thus particularly leaktight
- Pumping direction may be changed as required
- For applications which require a high pumping speed at pressures between 10-2 and 10-4 mbar (0.75 x 10-2 and 0.75 x 10-4 Torr)
- Used where the possibility of contamination due air ingress or pumped media leakage must be avoided
- Suction or pumping of high-purity or radioactive gases
- Is used in clean rooms were the air must not be recirculated by the motor‘s fan
- The required oil or PFPE filling is included in separate bottle (exceptions are marked)
- PFPE is used as standard
- Purged with nitrogen for corrosion protection
- Gasket in the intake flange with integrated dirt sieve
Technical DataRUVAC WS 501 W
50 Hz60 Hz
Nominal pumping speed m3/h (cfm)
Max. pumping speed m3/h (cfm)
with backing pump SOGEVAC
Ultimate partial pressure mbar (Torr)
Ultimate total pressure mbar (Torr)
Permissible cut-in pressure
RUVAC WS mbar (Torr)
Max. permissible pressure difference
during continuous operation mbar (Torr)
Main supply
Δ / Y V
Δ / Y V
Thermal class
Motor power, 50/60 Hz kW (hp)
Nominal speed, approx. (50/60 Hz) rpm
Max. permissible speed rpm
Type of protection IP
Cooling water connection
with inside thread
Cooling water consumption, min.
at inlet temperature, max. 25 °C l/h
Max. permissible cooling water pressure
bar
Oil filling for the bearing chamber
PFPE
vertical pumping action, approx.
l (qt)
horizontal pumping action, approx.
l (qt)
Connection flanges DN
Weight WS kg (lbs)
Noise level dB(A)
505 (297.4)
410 (241)
SV 200
< 8 x 10-3 (< 6 x 10-3)
< 4 x 10-2 (< 3 x 10-2)

100 (75)

80 (60)

200 / –
230 / 400
F
2.2 (3.0) / 2.4 (3.3)
3000/3600
6000
40

1/4 18" NPT

200

6
1. Filling / 2. Filling


0.85 (0.9) / 0.75 (0.79)

0.75 (0.79) / 0.7 (0.74)
63 ISO-K
130 (286.7)
< 63
606 (357)
530 (312)
SV 200
< 8 x 10-3 (< 6 x 10-3)
< 4 x 10-2 (< 3 x 10-2)

80 (60)

80 (60)

200-208 / –
265 / 460
F
2.2 (3.0) / 2.4 (3.3)
3000/3600
6000
40

1/4 18" NPT

200

6
1. Filling / 2. Filling


0.85 (0.9) / 0.75 (0.79)

0.75 (0.79) / 0.7 (0.74)
63 ISO-K
130 (286.7)
< 63
Technical DataWS/WSU 1001 WWS/WSU 2001 W
50 Hz60 Hz50 Hz60 Hz
Nominal pumping speed m3/h (cfm)
Max. pumping speed m3/h (cfm)
with backing pump SCREWLINE
Ultimate total pressure mbar
(Torr)
Permissible cut-in pressure
RUVAC WS mbar (Torr)
Max. permissible pressure difference
during continuous operation mbar (Torr)
Main supply
Δ / Y V
Δ / Y V
Thermal class
Motor power, 50/60 Hz kW
(hp)
Nominal speed, approx. (50/60 Hz) rpm
Max. permissible speed rpm
Type of protection IP
Cooling water connection
with inside thread
Cooling water consumption, min.
at inlet temperature, max. 25 °C l/h
Max. permissible cooling water pressure
bar
Oil filling for the bearing chamber

PFPE
vertical pumping action, approx. l
(qt)
horizontal pumping action, approx. l
(qt)
Connection flanges DN
Weight WS/WSU kg
(lbs)
Noise level dB(A)
1000 (589)
830 (489)
SP250
< 1 x 10-3
(< 7.5 x 10-4)

50 (37.5)

80 (60.0)

200 / –
230 / 400
F
4.0/4.4
(5.4/6.0)
3000/3600
6000
54

2x G 3/8 "

90

7
1. Filling /
2. Filling

1.95 / 1.75
(2.06 / 1.85)
1.2 / 1.1
(1.27 / 1.16)
100 ISO-K
228/233
(502.7/513.8)
< 68
1200 (707)
1000 (588)
SP250
< 1 x 10-3
(< 7.5 x 10-4)

20 (15.0)

50 (37.5)

200-208 / –
265 / 460
F
4.0/4.4
(5.4/6.0)
3000/3600
6000
54

2x G 3/8 "

90

7
1. Filling /
2. Filling

1.95 / 1.75
(2.06 / 1.85)
1.2 / 1.1
(1.27 / 1.16)
100 ISO-K
228/233
(502.7/513.8)
< 68
2050 (1207.5)
1780 (1044)
SP630
< 1 x 10-3
(< 7.5 x 10-4)

23 (17.25)

50 (37.5)

200 / –
230 / 400
F
7.5 /8.5
(10.2/11.6)
3000/3600
4200
54

2x G 1/2 "

150

7
1. Filling /
2. Filling

3.0 / 2.7
(3.17 / 2.85)
2.1 / 1.9
(2.22 / 2.00)
160 ISO-K
458/465
(1009.9/1025.3)
< 72
2460 (1449)
2080 (1224)
SP630
< 1 x 10-3
(< 7.5 x 10-4)

18 (13.5)

50 (37.5)

200-208 / –
265 / 460
F
7.5/8.5
(10.2/11.6)
3000/3600
4200
54

2x G 1/2 "

150

7
1. Filling /
2. Filling

3.0 / 2.7
(3.17 / 2.85)
2.1 / 1.9
(2.22 / 2.00)
160 ISO-K
458/465
(1009.9/1025.3)
< 72