SogevacŪ 500SV
| Technical Data | SogevacŪ 500SV | |
| 50 Hz | 60 Hz | |
| Nominal speed m3/h (cfm) Pumping speed m3/h (cfm) Ultimate partial pressure without gas ballast mbar (Torr) Ultimate total pressure with standard gas ballast mbar (Torr) Water vapor tolerance with gas 1 ballast mbar (Torr) with gas 2 ballasts mbar (Torr) Water vapor capacity with gas 1 ballast kg/h (qt/hr) with gas 2 ballasts kg/h (qt/hr) Noise Level dB (A) Motor Power/Nominal Speed kW (hp)/min^-1 Mains voltage V Type of protection IP Pump rated rotational speed min^-1 Thermal Switch (pump) Oil capacity l (qt) Weight (with oil)kg (lbs) Cooling Connections Intake DN Exhaust DN |
570 (335.7) 510 (300.4) ≤ 8 x 10^-2(≤ 6 x 10^-2) ≤ 1 (≤ 0.75) 40 (30) 60 (45) 13.0 (14.0) 19.5 (20.6) 71 11 (15)/(1500) 400 (+/- 10%) 55-F 880 (880) yes 35 (37)/38 (40) 630 Air (water) 100 PN & 100 ISO-K DN 100 PN & 100 ISO-K |
570 (335.7) 510 (300.4) ≤ 8 x 10^-2(≤ 6 x 10^-2) ≤ 1 (≤ 0.75) 40 (30) 60 (45) 13.0 (14.0) 19.5 (20.6) 71 11 (15)/(1500) 400 (+/- 10%) 55-F 880 (880) yes 35 (37)/38 (40) 630 Air (water) 4" ANSI 150-100 ISO-K 4" ANSI 150-100 ISO-K |